1. |
Project |
Coal based supercritical power plant, KIADB Industrial Area, Mulwad , Basavana Bagewadi Taluk, Bijapur district, Karnataka. |
2. |
Plant capacity |
1320 MW |
3. |
Plant configuration |
2 units of 660 MW each |
4. |
Location details |
|
|
|
Mulvad |
|
|
160 33’ 16.03” N |
|
|
750 43’ 44.52” E |
|
|
588 m |
|
|
Zone-II as per 1893 (part-I) 2002 |
|
- Distance from Basavanabagewadi town
|
18.5 km |
|
- Distance from National highway No218
|
0.5 km |
|
- Distance from state highway No
|
15.0 km |
|
- Distance from nearest Railway station Mulvad (Hubli-Bijapur)
|
5.0 km |
|
- Distance from nearest Airport Hubli
|
165 km |
|
- Distance from nearest sea port GOA
|
460 km |
5. |
Climatological data |
|
|
|
32.9 0C |
|
|
20.6 0C |
|
|
44.9 0C |
|
|
06.7 0C |
|
- Relative Humidity
- Max.
- Min.
|
85% 28% |
|
|
671.6 mm |
|
- Heaviest Rainfall in 24 hours
|
181.1 mm |
|
- No. of Rainy days in a year
|
40.5 |
|
- Highest monthly mean of wind speed
|
18.4 km/h |
|
- Lowest monthly mean of wind speed
|
03.8 km/h |
|
|
61.0 km/h |
|
- Design ambient temperature
|
50 0C |
6. |
Land |
Area in acres |
|
|
270.00 |
|
- Coal Handling plant marshalling yard
|
130.00 |
|
|
44.00 |
|
|
226.00 |
|
- Emergency Ash Dyke (MOEF Notification dt. 3.11.09)
|
220.00 |
|
- Corridors for Railway line Water pipe line
|
10.00 |
|
Total area in acres |
900.00 |
7. |
Water |
|
|
|
Krishna River - 16 km |
|
|
4,430 m3/hr |
8. |
Fuel |
|
|
a. Primary fuel |
Coal |
|
|
Indigenous - 70%
Imported - 30% |
|
|
Indigenous-CIL/coal blocks
Imported- S.A/Indonesia/ Australia |
|
|
3500 k.cal/kg |
|
|
5100 k.cal/kg |
|
- Annual coal requirement (with average GCV of coal as 3980 k.cal/kg & Station Heat Rate @ 2380 k.cal/kwh)
|
1) 5.92 Million M.T - @ 85% PLF
2) 6.92 Million M.T - @ 100% PLF |
|
b. Secondary fuel |
HFO/LDO |
|
|
From nearest refinery/oil depots |
|
- Secondary fuel requirement
|
9,900 KL/ year |
9. |
Steam Turbine Generator |
The steam Turbine will be single shaft, multi cylinders, tandem compound single reheat, regenerative, condensing unit directly coupled to AC Generator giving a continuous rated output at generator terminal. |
10. |
Steam Generator |
Steam Generator will be super-critical pressure balanced draft furnace, single reheat, radiant, dry bottom type, sliding pressure operating, suitable for outdoor installation designed for firing pulverized coal as main fuel. |
11. |
Cooling system |
Closed cycle cooling system using natural Draft cooling tower |
12. |
Chimney |
One 275 meter high twin flue RCC Stack |
13. |
Station operation philosophy |
Base Load |
14. |
Power Evacuation |
400 KV System for feeding to PGCIL grid. |
15. |
Ash |
|
|
|
2.01 M.MT |
|
|
Cement industries/SSI |